Product Description

Characteristic

In this discharge flow class, a very small and quiet pump
Since the impeller is non-contact, there are few particles
Maintenance-free as a pump
Filtration filter 0.1 M (changeable)
Add electrostatic removal function by permeation of CO2 (option)
Additional signal change with your factory can be changed additionally

Many of the other companies use magnet type pumps, but our company adopts a magnetic levitation type (Levitro) pump, realizing compact, high performance and maintenance free.

Device outline

This device boosts the water pressure from the factory side pure water supply line by a pump.

Performance

(1)Boosting ability

Max 0.25MPa Example ; When IN = 0.15 MPa, OUT = 0.40 MPa
(2)Flow rate
MAX ; 50L/min
(3)Water quality performance
Particle in liquid ; 10 pieces / mL or less Metal ion ; Fe、Cu、Ni、Cr、Zn、Na、K、AI
Each element is less than 10 pp

Device configuration

This device is constructed by housing the pipe mounting part and the electric mounting part inside the main body of the device.

(1)Device body
  1. Appearance dimension ; Width 500 mm × depth 1000 mm × height 1610 mm (not including projections)
  2. Material ; PVC
  3. Hue ; Ivory
  4. Gross weight ; 100Kg
(2)Piping relationship
  1. Piping material ; Clean PVC is adopted as the basis. Changes are also possible by consultation.
  2. Connection position relation ; Power supply and air are at the ceiling. Others will be on the back.
(3)Pump section
  1. Rotary pump with magnetically levitated impeller
  2. It becomes quiet and stable operation without vibration. Since there is no mechanical contact, no particles are generated.
  3. Basically maintenance is unnecessary.
  4. The size will be smaller than similar magnets pump.
(4)Filtration filter
  1. Pore size ; 0.1micron
  2. Material ; Polysulfone No hydrophilic treatment is required.
  3. Maker ; Japan pole
(5)Electricity, control section
  1. Control method ; Sequencer control
  2. Operation and display ; Touch panel (color)
 Regarding the contents of control specifications, interlocks, and external signals, we will respond on the basis of our standard form and meet with each user's convenience.

Utility

(1)Pure water
  1. Flow rate ; Max 50L/min
  2. Pressure ; 0.1~0.2MPa
  3. Conflict ; Clean PVC 30A union
(2)Compressed air (dry air)
  1. Pressure ; 0.4~0.7MPa
  2. Flow rate ; About 5L/min
  3. Conflict ; Rc1/4" Boss with female thread(SUS)
(3)Waste liquid
  1. There is no drainage, but the filter drain is internally HV stopped
(4)Drain pan drainage
  1. Likewise, HV stopping at the bottom of the back of the device
(5)Exhaust
  1. Forced exhaust by electric small FAN
  2. Displacement ; About 500L/min
  3. Conflict ; Release to the back
(6)Electrical
  1. Specification ; AC100V 15A、1φ 50Hz Terminal block connection
  2. Specification ; AC200V 15A、1φ 50Hz Terminal block connection

Dimensions